Strong and Weak Cation-Exchange Columns
for High-Resolution Separation of Proteins and MAbs
New! The Thermo Scientific ProPac? SCX column line has expanded to include the next generation ProPac
SCX-20 column. This column provides unequalled high resolution of
protein variants.
Please also see the Thermo Scientific MAbPac? SCX-10 column,
a strong cation-exchange column designed specifically for
high-resolution, high-efficiency analysis of monoclonal antibodies
(MAbs) and associated variants. This column is complimentary to the
industry-leading ProPac WCX-10 column for monoclonal antibody variant
analysis. The MAbPac SCX-10 offers an alternative selectivity and
provides higher resolution and efficiency for variant analysis of most
monoclonal antibody samples than the ProPac WCX-10 column.
ProPac
SCX-10 and WCX-10 strong and weak cation-exchange columns are based on a
nonporous core particle that results in high-efficiency peaks and
high-resolution separations of protein variants. A hydrophilic layer
prevents unwanted secondary interactions. A grafted cation-exchange
surface provides pH-based selectivity control and fast mass transfer for
high-efficiency separation and moderate capacity.
-
Characterization and quality control assessment of monoclonal antibodies and other proteins
-
Unequalled resolution
-
High-resolution separations with excellent sample recovery
-
Unmatched column-to-column and lot-to-lot reproducibility
-
Useful for characterization of related protein variants (e.g., deamidation and MAb lysine truncation variants)
-
Highly-efficient peaks with excellent sample recovery
-
Available in different dimensions and formats for flexibility in method development
The
ProPac SCX-10 is a strong cation-exchange column with sulfonate
functional groups, and the ProPac WCX-10 column has a carboxylate
functional group. Both are based on 10 μm nonporous, polymeric beads and
coated with a proprietary hydrophilic layer.
All ProPac columns
are manufactured and tested under the strictest specifications,
resulting in unmatched column-to-column and lot-to-lot reproducibility.
These columns are available as lot-select packages containing three
columns from a single lot or three columns from three different lots, to
assist quality control scientists in method validation.
ProPac SCX-10 Strong Cation-Exchange Column for the High-Resolution Separation of Protein Isoforms Specifications
|
Maximum operating pressure
|
3000 psi (21 MPa)
|
Maximum operating temperature
|
60 °C
Recommended operating temperature: <40 °C
|
Typical operating conditions
|
UV detection at 1 mL/min
Recommended flow rate: 1 mL/min
|
Mobile phase compatibility
|
pH 2–12; 80% compatible with acetonitrile, acetone, methanol.
Compatible with nonionic and zwitterionic detergents.
Incompatible with cationic detergents.
|
Resin composition
|
10-μm-diameter
core bead (55% cross-linked) grafted with a pellicular layer to which
are attached the sulfonate functional groups.
|
Anion-exchange capacity
|
< 100 μg protein on-column, depending upon the protein
(4 × 250 mm analytical column)
|
Column construction
|
PEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
|
ProPac WCX-10 Weak Cation-Exchange Column for the High-Resolution Separation of Protein Isoforms Specifications
|
Resin composition
|
10-μm-diameter
core bead (55% cross-linked) grafted with a pellicular layer to which
are attached the carboxylate functional groups.
|
Anion-exchange capacity
|
< 100 μg protein on-column, depending upon the protein
(4 × 250 mm analytical column)
|
Column construction
|
PEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
|
Maximum operating pressure
|
3000 psi (21 MPa)
|
Maximum operating temperature
|
60 °C
Recommended operating temperature: <40 °C
|
Typical operating conditions
|
UV detection at 1 mL/min
Recommended flow rate: 1 mL/min
|
Mobile phase compatibility
|
pH 2–12; 80% compatible with acetonitrile and acetone.
Compatible with nonionic and zwitterionic detergents.
Incompatible with cationic detergents.
|
SCX Analytical Columns
|
ProPac SCX-20 Analytical Column (4 x 250 mm)
|
074628
|
ProPac SCX-10 Analytical Column (4 x 250 mm)
|
054995
|
ProPac SCX-10 Analytical Column (2 x 250 mm)
|
063456
|
ProPac SCX-10 Semi-Preparative Column (9 x 250 mm)
|
063700
|
ProPac SCX-10 Semi-Preparative Column (22 x 250 mm)
|
SP5522
|
ProPac SCX-10 Lot Select Column Set (4 x 250 mm) (1 Lot of Resin)
|
SP5727
|
ProPac SCX-10 Lot Select Column Set (4 x 250 mm) (3 Lots of Resin)
|
SP5728
|
SCX Guard Columns
|
ProPac SCX-20 Guard Column (4 x 50mm)
|
074643
|
ProPac SCX-10G Guard Column (4 x 50 mm)
|
079930
|
ProPac SCX-10G Guard Column (2 x 50 mm)
|
063462
|
WCX Analytical Columns
|
ProPac WCX-10HT Analytical Column (4x 50mm)
|
074600
|
ProPac WCX-10 Analytical Column (4 x 100 mm)
|
SP5829
|
ProPac WCX-10 Analytical Column (4 x 150 mm)
|
SP6703
|
ProPac WCX-10 Analytical Column (4 x 250 mm)
|
054993
|
ProPac WCX-10 Lot Select 3 Column Set (4 x 250 mm) (1 Lot of Resin)
|
SP5512
|
ProPac WCX-10 Lot Select 3 Column Set (4 x 250 mm) (3 Lots of Resin)
|
SP5513
|
ProPac WCX-10 Analytical Column (2 x 250 mm)
|
063472
|
ProPac WCX-10 Semi-Preparative Column (9 x 250 mm)
|
063474
|
ProPac WCX-10 Semi-Preparative Column (22 x 250 mm)
|
SP5482
|
WCX Guard Columns
|
ProPac WCX-10G Guard Column (2 x 50 mm)
|
063480
|
ProPac WCX-10G Guard Column (4 x 50 mm)
|
054994
|